Page 174 - 8. Theatre stack
Pearl 2008 Manual - 16th July 2007
[Set Times]. to show the options.
You can also press the Live Time button (next to the wheels) to set the
times for the current step.
1> Press Softkey A-F to select the time parameter to set (the times
are described below).
2> Type the new time value using the numeric keypad and press
Enter
3> Press G to set Link on or off. If link is On the next cue will run
automatically after the Wait Out time. If off, you run each step
manually using the Go button.
4> Press Enter when you have finished. If you press Exit, any
changes you have made will be lost.
The times are:
A [Wait In] - Delay (after you press Go) before the fade in starts
B [Wait Out] - Delay (after you press Go for the next cue) before this
cue starts to fade out
C [Fade In] - Time to fade in
D [Fade Out] - Time to fade out
E [LTP Fade] - Time for the LTP (movement) channels to fade over
F [LTP Wait] - Delay before the LTP channels start to move
• Links are set to OFF by default, so that you press the Go button
for each cue. If you set links to On for a cue, the next cue will run
automatically after the “Wait Out” time.
• You can enter minutes as part of the time - press the decimal
point twice, a colon (:) will appear. e.g. to enter 20 mins 10.5
seconds, type 20..10.5 (the display will show 20:10.5).
8.2.2 Displaying the cue timings
Press View then Connect to display
the cue timings on the LCD screen.
When you are in theatre mode, the
cue timings are permanently
displayed on the VDU screen.
The list of cues automatically
moves so that the current step is
at the top.
For each step, the first line shows
the step number, whether links are
off or on for that step (Off=”-”,
On=down arrow), and whether the
step is Simple (S) or Complex (C)
(theatre stack steps are always
Complex.)
The second line shows the Wait In,
Wait Out and LTP Wait times for
the step.
The third line shows the Fade In, Fade Out and LTP fade times for the
step.